Filters
|
 |
GC SERIES COALESCING OIL REMOVAL
A majority of the oil aerosols emitted by air compressors are 2 micron and smaller. Most rust and scale typically found in compressed air
systems are 0.5 to 5 micron in size. Coalescing filters are specifically designed to remove submicronic oil, water and solid contaminates from compressed air.
- Standard S grade coalescing filters remove 99.97% of all aerosols in the 0.3 to 0.6 micron range.
|
Coalescing Filter |
|
Element |
Port Size |
Max. Pressure No Accessories |
A IN. |
B IN. |
C IN. |
D IN. |
Assy. Wt. |
GC-15 |
1 |
EGC-15 |
1/4" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,49 |
GC-20 |
1 |
EGC-20 |
3/8" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,47 |
GC-25 |
1 |
EGC-25 |
1/2" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,44 |
GC-40 |
1 |
EGC-40 |
3/8" NPT |
500 |
9,61 |
3,11 |
,55 |
N/A |
1,87 |
GC-50 |
1 |
EGC-50 |
1/2" NPT |
500 |
9,61 |
3,11 |
,55 |
N/A |
1,85 |
GC-80 |
1 |
EGC-80 |
3/4" NPT |
500 |
10,75 |
4,65 |
,98 |
N/A |
3,56 |
GC-100 |
1 |
EGC-100 |
1" NPT |
500 |
10,75 |
4,65 |
0,98 |
N/A |
3,29 |
GC-140 |
1 |
EGC-140 |
1" NPT |
500 |
14,25 |
4,65 |
0,98 |
N/A |
4,11 |
GC-255 |
1 |
EGC-255 |
1-1/4" NPT |
500 |
20,51 |
5,91 |
1,65 |
N/A |
12,11 |
GC-350 |
1 |
EGC-350 |
1-1/2" NPT |
500 |
20,51 |
5,91 |
1,65 |
N/A |
11,97 |
GC-450 |
1 |
EGC-450 |
2" NPT |
500 |
26,57 |
5,91 |
1,65 |
N/A |
14 |
GC-625 |
1 |
EGC-625 |
2" NPT |
500 |
31,61 |
5,91 |
1,65 |
N/A |
16 |
GC-800 |
1 |
EGC-800 |
2-1/2" NPT |
500 |
38,26 |
7,99 |
2,4 |
N/A |
35 |
GC-1000 |
1 |
EGC-1000 |
3" NPT |
500 |
38,26 |
7,99 |
2,4 |
N/A |
34,14 |
GC-1500T |
1 |
EGC-1500 |
3" NPT |
250 |
52,2 |
13 |
6 |
N/A |
200 |
GC-1500F |
1 |
EGC-1500 |
3" NPT |
250 |
65,2 |
13 |
6 |
38,23 |
215 |
GC-2000T |
1 |
EGC-2000 |
4" FLG |
250 |
55,69 |
22 |
5,89 |
N/A |
270 |
GC-2000F |
1 |
EGC-2000 |
4" FLG |
250 |
67 |
22 |
8 |
40 |
280 |
GC-3000F |
3 |
EGC-1000 |
6" FLG |
250 |
68 |
22 |
8 |
41 |
325 |
GC-4500F |
3 |
EGC-1500 |
6" FLG |
250 |
81 |
27 |
10,3 |
41 |
380 |
GC-6000F |
4 |
EGC-1500 |
8" FLG |
250 |
89 |
34 |
12 |
46 |
550 |
GC-10500F |
7 |
EGC-1500 |
10" FLG |
250 |
90 |
38 |
14 |
45 |
750 |
GC-16500F |
11 |
EGC-1500 |
12" FLG |
250 |
94 |
46 |
18 |
44 |
1300 |
|
 |
GP SERIES PARTICLE REMOVAL
- Particulate filters are recommended when the contaminate is a dry solid particle.
- The particle filter media provides a large holding area for solid contamination
|
|
Particulate Filter |
|
Element |
Port Size |
Max. Pressure No Accessories |
A IN. |
B IN. |
C IN. |
D IN. |
Assy. Wt. |
GP-25 |
1 |
EGP-25 |
1/4" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,49 |
GP-30 |
1 |
EGP-30 |
3/8" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,47 |
GP-40 |
1 |
EGP-40 |
1/2" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,44 |
GP-65 |
1 |
EGP-65 |
3/8" NPT |
500 |
9,61 |
3,11 |
,55 |
N/A |
1,87 |
GP-80 |
1 |
EGP-80 |
1/2" NPT |
500 |
9,61 |
3,11 |
,55 |
N/A |
1,85 |
GP-130 |
1 |
EGP-130 |
3/4" NPT |
500 |
10,75 |
4,65 |
,98 |
N/A |
3,56 |
GP-170 |
1 |
EGP-170 |
1" NPT |
500 |
10,75 |
4,65 |
0,98 |
N/A |
3,29 |
GP-230 |
1 |
EGP-230 |
1" NPT |
500 |
14,25 |
4,65 |
0,98 |
N/A |
4,11 |
GP-415 |
1 |
EGP-415 |
1-1/4" NPT |
500 |
20,51 |
5,91 |
1,65 |
N/A |
12,11 |
GP-600 |
1 |
EGP-600 |
1-1/2" NPT |
500 |
20,51 |
5,91 |
1,65 |
N/A |
11,97 |
GP-750 |
1 |
EGP-750 |
2" NPT |
500 |
26,57 |
5,91 |
1,65 |
N/A |
14 |
GP-1035 |
1 |
EGP-1035 |
2" NPT |
500 |
31,61 |
5,91 |
1,65 |
N/A |
16 |
GP-1330 |
1 |
EGP-1330 |
2-1/2" NPT |
500 |
38,26 |
7,99 |
2,4 |
N/A |
35 |
GP-1660 |
1 |
EGP-1660 |
3" NPT |
500 |
38,26 |
7,99 |
2,4 |
N/A |
34,14 |
GP-2500T |
1 |
EGP-2500 |
3" NPT |
250 |
52,2 |
13 |
6 |
N/A |
200 |
GP-2500F |
1 |
EGP-2500 |
3" NPT |
250 |
65,2 |
13 |
6 |
38,23 |
215 |
GP-3300T |
1 |
EGP-3300 |
4" FLG |
250 |
55,69 |
22 |
5,89 |
N/A |
270 |
GP-3300F |
1 |
EGP-3300 |
4" FLG |
250 |
67 |
22 |
8 |
40 |
280 |
GP-5000F |
3 |
EGP-1660 |
6" FLG |
250 |
68 |
22 |
8 |
41 |
325 |
GP-7500F |
3 |
EGP-2500 |
6" FLG |
250 |
81 |
27 |
10,3 |
41 |
380 |
GP-10000F |
4 |
EGP-2500 |
8" FLG |
250 |
89 |
34 |
12 |
46 |
550 |
GP-17500F |
7 |
EGP-2500 |
10" FLG |
250 |
90 |
38 |
14 |
45 |
750 |
GP-27000F |
11 |
EGP-2500 |
12" FLG |
250 |
94 |
46 |
18 |
44 |
1300 |
|
GA SERIES HYDROCARBON REMOVAL
- The activated charcoal adsorbing element will remove final trace amounts of hydrocarbon contaminants.
- Preparation for breathing air; hydrocarbon vapor removal
|
Absorber Filter |
|
Element |
Port Size |
Max. Pressure No Accessories |
A IN. |
B IN. |
C IN. |
D IN. |
Assy. Wt. |
GA-15 |
1 |
EGA-15 |
1/4" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,49 |
GA-20 |
1 |
EGA-20 |
3/8" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,47 |
GA-25 |
1 |
EGA-25 |
1/2" NPT |
500 |
7,13 |
3,11 |
,55 |
N/A |
1,44 |
GA-40 |
1 |
EGA-40 |
3/8" NPT |
500 |
9,61 |
3,11 |
,55 |
N/A |
1,87 |
GA-50 |
1 |
EGA-50 |
1/2" NPT |
500 |
9,61 |
3,11 |
,55 |
N/A |
1,85 |
GA-80 |
1 |
EGA-80 |
3/4" NPT |
500 |
10,75 |
4,65 |
,98 |
N/A |
3,56 |
GA-100 |
1 |
EGA-100 |
1" NPT |
500 |
10,75 |
4,65 |
0,98 |
N/A |
3,29 |
GA-140 |
1 |
EGA-140 |
1" NPT |
500 |
14,25 |
4,65 |
0,98 |
N/A |
4,11 |
GA-255 |
1 |
EGA-255 |
1-1/4" NPT |
500 |
20,51 |
5,91 |
1,65 |
N/A |
12,11 |
GA-350 |
1 |
EGA-350 |
1-1/2" NPT |
500 |
20,51 |
5,91 |
1,65 |
N/A |
11,97 |
GA-450 |
1 |
EGA-450 |
2" NPT |
500 |
26,57 |
5,91 |
1,65 |
N/A |
14 |
GA-625 |
1 |
EGA-625 |
2" NPT |
500 |
31,61 |
5,91 |
1,65 |
N/A |
16 |
GA-800 |
1 |
EGA-800 |
2-1/2" NPT |
500 |
38,26 |
7,99 |
2,4 |
N/A |
35 |
GA-1000 |
1 |
EGA-1000 |
3" NPT |
500 |
38,26 |
7,99 |
2,4 |
N/A |
34,14 |
GA-1500T |
1 |
EGA-1500 |
3" NPT |
250 |
52,2 |
13 |
6 |
N/A |
200 |
GA-1500F |
1 |
EGA-1500 |
3" NPT |
250 |
65,2 |
13 |
6 |
38,23 |
215 |
GA-2000T |
1 |
EGA-2000 |
4" FLG |
250 |
55,69 |
22 |
5,89 |
N/A |
270 |
GA-2000F |
1 |
EGA-2000 |
4" FLG |
250 |
67 |
22 |
8 |
40 |
280 |
GA-3000F |
3 |
EGA-1000 |
6" FLG |
250 |
68 |
22 |
8 |
41 |
325 |
| | | | |