Dryers
|
 |
GRF SERIES
NON-CYCLING REFRIGERATED AIR DRYER |
Great Lakes Air Dryers are built by experienced assemblers that take good old fashion pride in their workmanship. Backed up
with a 5 year unconditional parts warranty, Great Lakes refrigerated dryers are the best solution for a dry clean air. |
Great Lakes Air Dryers - Technical Specifications |
In accordance with NFPA and CAGI standards, dryer capacities are based on 100°F and 100
PSIG Inlet, 100°F Ambient, 35°F range PDP, and maximum pressure drop of 5 PSIG. |
Model |
Capacity (pi3/min.) @ 35-50°F Dewpoint |
Available Condition |
Available Voltage |
Refrig. Comp. HP |
Inlet / Outlet |
Max. Inlet Pressure |
Dimensions (inches) |
Weight (lbs) |
35° F |
50°F |
L |
W |
H |
GRF-5 |
5 |
6 |
A |
A |
1/6 |
3/8 OD |
250 PSIG |
15 |
13 |
10 |
54 |
GRF-10 |
12 |
14 |
A |
A |
1/6 |
3/8 OD |
250 PSIG |
15 |
13 |
10 |
54 |
GRF-20 |
18 |
22 |
A |
A |
1/5 |
1/2 NPT |
250 PSIG |
21 |
15 |
19 |
102 |
GRF-25 |
25 |
30 |
A |
A |
1/4 |
1/2 NPT |
250 PSIG |
21 |
15 |
19 |
106 |
GRF-40 |
40 |
48 |
A |
A |
1/4 |
1/2 NPT |
250 PSIG |
21 |
15 |
19 |
110 |
GRF-50 |
50 |
60 |
A,E |
A |
1/3 |
3/4 NPT |
250 PSIG |
25 |
19 |
18 |
125 |
GRF-75 |
75 |
90 |
A,E |
A,B,C,D |
1/2 |
3/4 NPT |
250 PSIG |
25 |
19 |
18 |
140 |
GRF-100 |
100 |
120 |
A,E |
A,B,C,D |
1/2 |
1-1/2 NPT |
250 PSIG |
33 |
25 |
34 |
227 |
GRF-125 |
125 |
150 |
A,E |
A,B,C,D |
3/4 |
1-1/2 NPT |
250 PSIG |
33 |
25 |
34 |
263 |
GRF-150 |
150 |
180 |
A,E |
A,B,C,D |
3/4 |
1-1/2 NPT |
250 PSIG |
33 |
25 |
34 |
265 |
GRF-200 |
200 |
240 |
A,E |
B,C,D |
1 |
1-1/2 NPT |
250 PSIG |
33 |
25 |
34 |
300 |
GRF-250 |
250 |
300 |
A,E |
C,D |
1-1/2 |
1-1/2 NPT |
250 PSIG |
33 |
25 |
34 |
325 |
GRF-300 |
300 |
360 |
A,E |
C,D |
1-1/2 |
2 NPT |
250 PSIG |
33 |
25 |
34 |
380 |
GRF-400 |
400 |
480 |
A,E |
C,D |
2 |
2-1/2 NPT |
250 PSIG |
45 |
32 |
46 |
600 |
GRF-500 |
500 |
600 |
A,E |
C,D |
3 |
2-1/2 NPT |
250 PSIG |
45 |
32 |
46 |
655 |
GRF-650 |
650 |
780 |
A,E |
C,D |
3 |
2-1/2 NPT |
250 PSIG |
45 |
32 |
46 |
1100 |
GRF-800 |
800 |
960 |
A,E |
C,D |
4 |
3 NPT |
150 PSIG |
57 |
35 |
61 |
1500 |
GRF-1000 |
1000 |
1200 |
A,E |
C,D |
5 |
3 NPT |
150 PSIG |
57 |
35 |
61 |
1700 |
GRF-1200 |
1200 |
1440 |
A,E |
C,D |
5-1/2 |
3 NPT |
150 PSIG |
57 |
35 |
72 |
2000 |
GRF-1500 |
1500 |
1800 |
A,E |
C,D |
7-1/2 |
4 FLG |
150 PSIG |
59 |
57 |
75 |
2600 |
GRF-1750 |
1750 |
2100 |
A,E |
C,D |
10 |
4 FLG |
150 PSIG |
59 |
57 |
75 |
3000 |
GRF-2000 |
2000 |
2400 |
A,E |
C,D |
10 |
4 FLG |
150 PSIG |
59 |
57 |
75 |
3500 |
GRF-2500 |
2500 |
3000 |
A,E |
C,D |
15 |
6 FLG |
150 PSIG |
90 |
72 |
72 |
3800 |
GRF-3000 |
3000 |
3600 |
E |
C,D |
15 |
6 FLG |
150 PSIG |
90 |
72 |
72 |
3900 |
GRF-3500 |
3500 |
4200 |
E |
C,D |
20 |
6 FLG |
150 PSIG |
120 |
75 |
80 |
4400 |
GRF-4000 |
4000 |
4800 |
E |
C,D |
20 |
6 FLG |
150 PSIG |
140 |
95 |
90 |
5100 |
Available Voltage : A= 120-1-60 : B= 240-1-60 : C= 208/240-3-60 : D=440/480-3-60 |
Available Condition : A = air cooling : E = water cooling |
Water cooled compressors have a 6% higher capacity. |
Products dimensions can change without notice. |
|
Standard Design Features
- 5 YEAR NON PRO-RATED WARRANTY
- Tecumseh Condensing Units
- Power Coated Heavy Duty Steel Cabinets
- Maintenance friendly design
- Non-fouling, self cleaning, smooth surface, copper heat exchanger.
- Refrigeration analyser gauge.
- Automatic expansion valve system.
- On/off switch.
- Power On light.
- Electrical accessories junction box.
- Compressor overload protection
- Relay contactor.
- Auto drain.
|
 |
|
 |
Top
|
|
|
|
|